Professor Milorad Home Page |
||
|
PUBLICATIONS
Thesis, books,
chapters, and journal articles accomplishments
Publications edited by Prof. BojicConference proceedings
Conference
summaries
Submitted papers
Selected
software Lectures
IV. Publication accomplishments
a) Thesis, books, chapters, and journal articles 1.
Bojic, M.,
"Two Dimensional Mathematical Model of Non-Buoyant Jet in a
Cross-Flow", MSc Thesis, Department of Mechanical and Aerospace
Engineering, Syracuse University, Syracuse, N.Y., USA, 1977, (99 pages). 2.
Bojic, M. and
Eskinazi, S., "Two Dimensional Mathematical Model of a Non-Buoyant Jet
in a Cross-Flow", AIAA Journal, 17, 10, (1979) pp. 1050-1054. 3.
Bojic, M., and
Arsic, Z., "Characteristics of simple resistance thermometer made at
Mechanical engineering faculty at Kragujevac ", Motor Vehicles, Engines,
IX, 52, (1983) pp. 45-63. (In Serbian) 4.
Bojic, M.,
Marjanovic, B., Babic, M., " Characteristics of device for rotation of
anemometer probe ", Contemporary Transport, 5,1-2, (1983)
pp. 363-367. (In Serbian) 5.
Bojic, M.,
"Experimental research on a turbulent air jet in a cross air stream
under variable jet temperature", doctoral dissertation, Faculty of
Mechanical Engineering at Kragujevac, Svetozar Markovic University,
Kragujevac, Yugoslavia, 1984 (272 pages). (In Serbian) 6.
Bojic, M.,
"Convection," Basis of Heat Transfer - Seminar Material, Bojic, M.,
edr., Svetozar Markovic University, Kragujevac, Yugoslavia 1985 (14 pages).
(In Serbian) 7.
Bojic, M.,
"Heat Transmission," Basis of Heat Transfer - Seminar Material,
Bojic, M., edr., Svetozar Markovic University, Kragujevac, Yugoslavia 1985 (8
pages). (In Serbian) 8.
Bojic, M.,
"State of art in experimental research on isothermal mixing of a
non-buoyant jet and a cross stream," in
Proceedings of Mechanical Engineering Faculty at Kragujevac, 3,
Obrovic, B., edr., Svetozar Markovic University, Kragujevac, Yugoslavia
(1985) pp. 7-15.(In Serbian) 9.
Bojic, M.,
"Review of some possible cases of non rational use of energy in
industry. Measures for their rationalization and examples of effects of such
measures ", Energy Management in Industry as new Energy Source - Seminar
Material, Bojic, M., edr., Svetozar Markovic University, Kragujevac,
Yugoslavia 1986 (5 pages). (In Serbian) 10. Bojic, M., "Investigation of possibilities
for rational energy management at industrial power plants: mass and energy
balancing ", Energy Management in Industry as new Energy Source -
Seminar Material, Bojic, M., edr., Svetozar Markovic University, Kragujevac,
Yugoslavia 1986 (5 pages). (In Serbian) 11. Bojic, M., an Air Jet in a Cross Stream,
Monograph, Svetlost, Kragujevac, Yugoslavia 1987 (pages 274). (In Serbian) 12. Bojic, M., Hnatko, E., Heat Engineering,
University textbook, Svetozar Markovic University, Mechanical Engineering
Faculty, Kragujevac, Yugoslavia 1987 (pages 229). (In Serbian). 13. Bojic, M., "Ten year projects (1976-1986)
in energy research, development and application of heat exchangers and
combustion processes in countries that are members of international agency
for energy ", in Heat exchangers and industrial furnaces, Bojic, M.
edr., Svetozar Markovic University, Kragujevac Yugoslavia (1987) pp. 1-11.
(In Serbian) 14. Bojic, M., Petrovic, M., "Rational
consumption of energy in breweries," Brewery, 20, 2, (1987) pp. 83-93.
(In Serbian) 15. Bojic, M., "Contribution to the
recuperation theory of passive
production processes", in Economy of heat management, Bojic, M. edr.,
Svetozar Markovic University, Kragujevac Yugoslavia (1988) pp. 1-14. (In
Serbian) 16. Bojic, M., Zaric, Z., "Experimental
Investigation of a Heated Non buoyant Turbulent Jet in a Cross-stream:
Temperature Field", Theoretical and applied mechanics, 14/88, 1988, pp.
17-30. 17. Bojic, M., "Some of mathematical models of
energy management developed at Mechanical engineering faculty at Kragujevac
", Heat in industry, 3, (1988) pp. 20-26(In Serbian) 18. Randzic, D., Bojic, M., " Use of refuse
material for heating ", Heat in industry, 3,1988, pp. 27-38. (In
Serbian) 19. Bojic,M., Cekovic,G., Vidojevic,S.,
Knezevic,V., Nikolic,T., Zdravkovic., "Contribution to Energy Modeling
of Rational Energy Usage in Industrial Buildings", in Clima 2000 V:
General Problems of Energy, Refrigeration Components and Systems, P. Novak, B. Todorovic, E. Kulic, eds.,
RHEVA, Amersfoort, Netherlands (1989) pp. 115-120. 20. Bojic, M. "Thermal Development of Heated
Non-Buoyant Jet in the Cross-Stream," Archives of Thermodynamics, 10,
1-2 (1989) pp. 51-63. 21. Bojic,M., Skladzien,J., "Energy management
in breweries ", Scientific books of High Engineering School at Opolo,
Series: Mechanics 36, 149 (1989) pp.123-137. (In Polish) 22. Bojic,M., "Experimental Investigations of
a Heated Non buoyant Jet in a Cross-stream: Temperatures and their
Fluctuations", Scientific books of High Engineering School at Opolo,
Series: Mechanics, 36, 149 (1989) pp. 139-148. 23. Bojic,M., Lukic,N., "Mathematical modeling
of car coolers", Flag, VII (1989) pp. 7-14. (In Serbian) 24. Bojic, M., "Some of mathematical models of
energy management developed at Mechanical engineering faculty at Kragujevac
", Flag, VII, 24 (1989) pp.
19-22. (In Serbian) 25. Bojic, M., "Energy and Energy Cost Flow
inside Industrial Building", from Heat And Mass Transfer In Building
Material And Structure, Chaddock, J. Todorovic, B., eds., Hemisphere
Publishing Company, Washington, D.C., USA (1990) pp. 457-464. 26. Bojic,M., Lukic, N., Milovanovic, M., "
Software for analyses of energy use and selection of steam-trap types in industrial steam-condensate systems
", in Proceedings of Mechanical
Engineering Faculty at Kragujevac, 4, Josifovic, D., edr. Svetozar Markovic
University, Kragujevac, Yugoslavia (1990) pp. 231-237.(In Serbian). 27. Bojic, M., "Evaluation of Steam-Trap Types
using a Non -Integer Rating Method," Energy-The International Journal,
15, 9 (1990) pp.759-765. 28. Bojic,M., Lukic, N., Milovanovic, M.,
"Operation of software for analysis of energy use and selection of types
of steam traps in industrial steam and condensate systems ", Heat in
Industry, 4 (1990) pp.12-19, (In Serbian). 29. Bojic, M., "Computer Package for
Calculation of Energy Savings in NonResidential Buildings", Scientific
books of Technical Univesity of Slaska in Gliwice: series Energetics, 112
(1991) pp. 125-142. 30. Bojic, M., "Energy systems in industry:
Industrial Buildings and Steam-trap Types", Scientific books of
Technical Univesity of Slaska in Gliwice: series Energetics, 112 (1991) pp.
145-156. 31. Skladzien,J., Hanuszkiewicz-Drapala,M., Bojic,M.,
"Balance of energy exergy for new type of installation for removal of
odor ", Scientific books of High Engineering School at Opolo, Series:
Mechanics, 40, 163 (1991) pp. 149-162. (In Polish) 32. Bojic,M. " Laboratory for thermodynamics
and heat engineering- fundamental, applied and development research", in
Faculty of Mechanical Engineering, Kragujevac University Lazic, M., edr.,
Kragujevac University, Kragujevac, Yugoslavia (1993) pp. 36-37. (In Serbian) 33. Bojic, M., "Mathematical Model of Heat
Recovery in a Space Heating and
Ventilation System," Energy-The International Journal, 18, 1 (1993) pp.
49-61. 34. Bojic, M., Influence of Tool-Shop-Envelope
Parameters on Heat Recovery in a Space-Heating and Ventilation System, Facta Universitatis,
Series: Mechanical Engineering, 1, 1 (1994) pp.65-71. 35. Bojic, M., Jadaneant, M.,“On Some Energy
Incidents in Steam and Condensate Systems,” Engineering Scientific Bulletin
of Technical University of Timisoara, 39, 53 (1994) pp. 80-91. 36. Bojic, M., Negrea, V.D., “Multiple
Misapplication Influence of Critical Operating Conditions to Steam Traps in
Steam and Condensate Systems,” Engineering Scientific Bulletin of Technical
University of Timisoara, 39, 53 (1994) pp. 92-98. 37. Vasic, M., Bojic, M., Lukic, N., “Optimization
of energy savings in industrial energy systems by using linear programming,”
Air conditioning, Heating, Cooling, 4 (1994) pp.51-54. (in Serbian) 38. Bojic, M., Ilic, G., On Possibilities of Coarse
Tuning of Steam and Condensate Systems, Heat Engineering, XX, 1-2 (1994) pp.
77-83. (In Serbian) 39. Bojic, M., Petrovic, V., “The influence of
steam leaking in technology of industrial building to use of refuse heat when
the building is locally ventilated,” in 35 years of Mechanical Engineering Education
at Kragujevac, Monograph, Josifovic, D., edr., Kragujevac University,
Kragujevac, Yugoslavia 5 (1995) pp. 253-262. (In Serbian) . 40. Bojic, M., Lukic, N., Trnobransky, K.,
"Linear Programming Applied to an Industrial Building with Several
Available Hot Refuse Flows," Energy - The international journal, 20,10
(1995) pp. 1067-1074. 41. Bojic, M. Trnobransky, K., "Influence of
Hot Tool Parameters to Heat Recovery in a Space and Ventilation System"
Energy - The International Journal, 20, 10 (1995) pp. 1075-1079. 42. Lukic, N.,
Bojic, M., “The influence of temperature of rooms and environment to
optimal control of heat recovery device of thermally heavy building,” Heat
Engineering, XXI, 1-2 (1995) pp. 103-110. (In Serbian) 43. Tomic, M., Bojic, M., Jankez, G., Gosic, D.,
“Some results of the measurement of energy consumption in pusher furnaces
when different fuels are applied,” Heat Engineering, XXI, 1-2 (1995) pp.
111-119. (In Serbian) 44. Bojic, M., Mathematical Modeling of Energy
Consumption in Industry by using Energy-Object-Network Methodology,
Monograph, Manual of Process Engineering and technology Series, 8, Process
Engineering Publisher, Praha, Czech Republic (1996) 38 pages. 45. Bojic, M., Lukic,N., Hrdlicka, F., "Control Regions for Heat Recovery in an
Industrial Building with Several available Hot Refuse Flows," Energy-
The International Journal, 21, 12 (1996) pp.1227-1231. 46. Bojic, M., Bojic, S., "Design of
Installations for an Optimal Use of Industrial Waters by using Pinch
Methodology," Water and Sanitary Techniques, 26, 3 (1996) pp.5-16 (in
Serbian). P-90% 47. Bojic, M., Knezevic, V., Lukic, N., Malesevic,
J., “Influence of the outside temperature
on the operation of devices for the use of refuse heat when building
is locally ventilated,” Engineering Journal, Series: Mechanical Engineering
45, 3-4, (1996) pp..M71-M76. (in Serbian) 48. Bojic, M., "Cogeneration of Power and Heat
by using Endoreversible Carnot Engine," Energy conversion and
management, 38, 18 (1997) pp. 1877-1880. 49. Bojic, M., Loveday, D., "The Influence of
the Distribution of Isolation and Masonry in Three Layered Building Envelope
on Thermal Behavior of the Building," Energy and Buildings,26/2 (1997)
pp.153-157. 50. Bojic, M, Milovanovic, M., Loveday, D.,
"Research on Thermal Behavior of Buildings with Slanted Roof,"
Energy and Buildings, 26/2 (1997) pp.145-151. 51. Bojic, M., Raškovic, P., Radojkovic, N., “An
Influence of Boiler-Recovery-Heat Exchanger to Boiler Size- a Tool Shop
Example,” Facta Universitatis, Series: Mechanical Engineering, 1, 4 (1997)
pp. 447-457. 52. Bojic, M. Savanovic, G. Trifunovic, N. Radovic
L. and Šaljic, D. “Thermoelectric Cooling of a Train Carriage by using a
Coldness-Recov9ery Device,” Energy-The International Journal, 22, 5 (1997)
pp. 493-500. 53. Bojic, M Trifunovic, N Papadakis, G Kyritis, S.
“Numerical simulation, technical and economic evaluation of air-to-earth heat
exchanger coupled to a building.” Energy-The international Journal, 22, 12
(1997) pp. 1151-1158. 54. Bojic, M., Trifiunovic, N., “Mixed Integer
Linear Programming Optimization of Heat Distribution within a Local Heating
System,” Indoor + Built Environment 6 (1997) pp. 282-290. 55. Gustafsson, S.I., Bojic, M., “Optimal
heating-system retrofits in residential buildings,” Energy-the International
Journal, 22, 9 (1997) pp. 867-874. 56. Bojic, M., “Energy Consumption in Industry by
using Energy-object-network methodology,” from Actual Topics in Energy
Management (Consumption-Production-Modeling) edited by M. Bojic, Center for
Energy Management, Mechanical Engineering Faculty at Kragujevac, Series:
Monographs, 5, (1998) pp. 43-76. 57. Bojic, M., Stojanovic, B., and
Mourdoukoutas,P., "MILP Optimization of Energy Systems Having a
Condensing Turbine," Energy- The International Journal, 23, 3 (1998)
pp.231-238. 58. Bojic, M., Stojanovic, B., "MILP Optimization
of a CHP Energy System," Energy conversion and management, 39, 7, (1998)
pp. 637-642. 59. Bojic, M., Tomic, M., “An Influence of Refuse -gas-fuel use to Energy Consumption of an Industrial Pusher Furnace,” Energy - The International Journal, 23, 9, (1998) pp.767-775. 60. Bojic, M., Papadakis, G., Kyritsis, S., Energy from a two-pipe, earth –to-air heat exchanger, Energy-The interrnational journal, 24 (1999) pp. 519-523. 61. Bojic, M., Trifunovic, N., Linear Programming Optimization of Heat Distribution in a District- Heating System by Valve Adjustment and Substation Retrofit," Building and Environment, 35, 2 (2000) pp. 151-159. 62. Bojic, M., Lukic, N., Numerical Evaluation of Solar-Energy Use through Passive Heating of Weekend Houses in Yugoslavia, Renewable energy, 20,2 (2000) pp.207-222. 63. Bojic, Lukic, Influence of Heat Gains on Heat Recovery in an Two-Zone-Industrial Building with several available Hot Refuse Flows," Building and Environment, 35 (2000) 511-517 64.
Bojic, M., Mourdoukoutas, P., Energy Saving does not yield CO2 Emissions
Reductions: the Case of Waste Fuel Use in a Steel Mills, Applied Thermal
Engineering, 20 (2000) 963-975 65. Bojic, M., "Optimization of Heating and Cooling of a Building by an Installation Employing Refuse and Renewable Energy, "Renewable Energy, 20 (2000), 453-465 66. Kalogirou, S., Bojic, M., Artificial neural networks for the evaluation of a passive solar building energy consumption, Energy, 25 (2000) 479-491 67.
Bojic, M., Trifunovic, N., Gustafsson, S. I.
"Mixed 0-1 Sequential Linear Programming Optimization of Heat
Distribution in a District Heating System, " Energy and Buildings, 32
(2000) 309-317. 68. Bojic, M., Yik, F.,
Burnett, J., Energy Behavior of High-Rise Residential 69. M. Bojic, F. Yik, P. Sat, Influence of thermal insulation position in building envelope on the space cooling of high-rise residential buildings in Hong Kong, Energy and Building, 33/6 (2001) pp 569-581. 70. Bojic M, Yik F, Wan K, Burnett J, Investigation of cooling loads in high-rise residential buildings in Hong Kong, STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 47 (8), (2001) 491-496 71. Bojic, M., Lee, M., Yik, F., Flow and temperatures outside a high-rise residential building due to heat rejection by its air- conditioners, Energy and Buildings, Vol. 33/7 (2001) 737-751. 72. Bojic, M., Lee, M., Yik, F., Flow inside a recessed space outside a high-rise residential building due to heat rejection by one air conditioner per story, HKIE Transactions, 8 (2), (2001) pp. 48-54. 73. Bojic, M., Lee, M., Yik, F., Influence of a recessed space to flow due to air-conditioner heat rejection, Energy and Buildings, Vol. 34/1 (2002) 33-43. 74. Bojic, M., Yik, F., Sat, P., Energy performance of windows in high-rise residential buildings in Hong Kong, Energy and Buildings, Vol. 34/1, (2002) 71-82. 75. Bojic, M., Yik, F., Leung, W., Thermal insulation of cooled space in high-rise residential buildings in Hong Kong, Energy Conversion and Management, 43/2 (2002) 165-183. 76. Bojic, M., Dragicevic, S., MILP Optimization of Energy Supply by Using a Boiler, Condensation Turbine and Heat Pump, Energy Conversion and Management, Vol. 43/4, March (2002) 591-608. 77. Bojic, M., Lukic, N., Evaporative three-finger Thermosyphon, Energy Conversion and Management, Vol. 43/5, March (2002), 709-720. 78. Bojic, M., Yik, F., Wan, K., Burnett, J., Influence of envelope and partition characteristics on the space cooling of high-rise residential buildings in Hong Kong, Building and Environment, 37/4 (2002) 347-355. 79. M., Bojic, M. Lee, F. Yik, J. Burnett, Influence of clearances on the energy performance of window-type air-conditioners at the same level outside residential buildings, Building and Environment, 37/7 (2002) 713-726. 80. Bojic, M., Kalogirou, S., Petronijevic, K., Modeling and simulation of a Solar domestic water heating system using a time marching model, Renewable energy, 27/3 (2002) 103-114. 81. Bojic, M., Yik, F., Lo T.Y. Locating Air-conditioners and Furniture inside Residential Flats to Obtain Good Thermal Comfort, Energy and Buildings, 34/7 (2002) 745-751. 82. Bojic, M., Yik, F., Lee, M., Influence of heat rejected by air conditioners to flow inside a recessed space with one plate, Transactions of ASME, Article in press, 2002. 83. Bojic, M., Yik, F., Lee, M. Influence of air conditioning exhaust on exterior, recessed space, Building research and information, Article in press, 2002. 84. M. Bojic, F. Yik, M. Lee, Influence of Plates on Flow inside a Recessed Space Generated by Rejected Heat, Building and Environment, Article in press, 2002. b. Publications edited by Prof. Bojic: 1.
Basis of Heat
Transfer-Seminar Material, Svetozar Markovic University, Kragujevac, Yugoslavia,
1985 (53 pages). (In Serbian) 2.
Energy Management
in Industry as new Energy Source-Seminar Material, Svetozar Markovic
University, Kragujevac, Yugoslavia,1986 (10 pages). (In Serbian) 3.
Heat exchangers and
industrial furnaces, Svetozar Markovic University, Kragujevac, Yugoslavia,
1987. (In Serbian) 4.
Economy of heat
management, Svetozar Markovic University, Kragujevac, Yugoslavia,1988. (In
Serbian) 5.
Actual topics on
energy management (Consumption-Production-Modeling), Kragujevac University,
Kragujevac, Yugoslavia, 1998. (In Serbian and English) c. Conference proceedings
1.
Babic M., Bojic,
M., Slavkovic, R., Markovic, M., Milanovic, S., " Contribution to
mathematical modeling of indirect heat exchangers in industrial paint shops
", Proceedings of XIII seminar on heating, cooling and air-conditioning,
Belgrade, Yugoslavia, (1982) pp. 233-241. (In Serbian). 2.
Bojic, M., Arsic,
Z., Ilic, G., "Circuit of thermometer amplification with electronic
compensation of cool part ", Proceedings of scientific-expert
meeting on 25 Years of Mechanical Engineering - Nish, Nish, Yugoslavia
(1985) pp. 169-177. (In Serbian) 3.
Ilic, G., Bojic,
M., "Application of K-e model of
turbulence to investigation of thermal and dynamical development of heated
jet in bounded fluid stream ", Proceedings of scientific-expert meeting
on 25 Years of Mechanical Engineering - Nish, Nish, Yugoslavia (1985) pp.
226-244. (In Serbian) 4.
Bojic, M.,
"Possibilities for energy management of industrial power plants during
energy production, transport and consumption", Proceedings of 16-th
congress on heating, cooling and air-conditioning, Belgrade, Yugoslavia
(1985) pp. 75-81. (In Serbian) 5.
Bojic, M.,
"Experimental Investigations of a Heated Non buoyant Jet in a
Cross-Stream: Temperatures and their Fluctuations”, Proceedings of the Eight
International Heat Transfer Conference, Volume 3, San Francisco, CA, USA
(1986) pp. 1171-1176. 6.
Bojic, M., Ilic,
G., "Prediction of Velocity Field of a Deflected Non buoyant Turbulent
Jet", Pr3oceedings of 25-th Symposium Modeling in Mechanics, Kudowa,
Poland (1986) pp. 48-55. 7.
Bojic, M.,
"The Contribution to Methodology Development of Analysis of Rational
Energy Usage in Technological Processes", Proceedings of International
Scientific Conference on Energy and Development, Zagreb, Croatia (1986) pp.
543-554. 8.
Bojic, M.,
Milenkovic, P., "Efficiency of valve heat regenerator ",
Proceedings of 19-th congress on heating, cooling and air-conditioning,
Belgrade, Yugoslavia (1988) pp.322-332. (In Serbian) 9.
Bojic,M.,
Lukic,N., Contribution to Mathematical Modeling of Finned Cross Flow
Recuperators, Proceedings of VII Symposium of Heat and Mass Transfer,
Warszawa, Jadwisin, Poland (1989) pp.39- 44. 10. Bojic,M., "Some Research On Several Winter
Thermally Light Space Heating Systems With Coupled Heat Recovery From Their
Local Ventilation", Proceedings of International Conference on Energy,
Ecology and Economy, Zagreb, Croatia (1991) pp. 89-96. 11. Bojic,M., "Flow of cumulative exergy in
steam and condensate systems",
Preprints I of 4th World Congress of Chemical Engineering, STRATEGIES 2000,
Karlsruhe, Germany (1991) pp. 4.1-20/1-4.1-20/3. 12. N.Lukic, M.Bojic, "Zone-Temperature
Influence on Heat Recovery in an Industrial Building with Several Available
Hot Refuse Flows," Proceedings of IV National Conference on Heat
Engineering, Timisoara, Romania (1994) pp.214-219. 13. M.Bojic, N.Lukic, "Influence of Stem-Loss
Parameters on Heat Recovery in an Two-Zone-Industrial Building with Several
Available Hot Refuse Flows", Proceedings of the Fourth International
Conference RoomVent'94. on Air Distribution in Rooms, Volume 2: Engineering
Methods, Krakow, Poland (1994) pp. 409-414. 14. Bojic, M., Zekavica, O., Vasovic, D.,
"Thermo-hydraulics of use of refuse heat", Proceedings of Simpozium
on Thermohydraulic processes in energetics-Thermohydraulics '94, Belgrade,
Yugoslavia (1994) pp. C5-1 C5-8 (In Serbian) 15. Bojic, M., Trifunovic, N., Papadakis, G.,
Kyritsis, S., “Application of Heat exchanger Earth –Air for Heating and Cooling
of Buildings”, Proceedings of the 25th Congress on Heating, cooling and air
conditioning, Belgrade, Yugoslavia (1994) pp. 219-226. 16. Bojic, M., Lukic, N., “Possible malfunction in
operation of steam traps and recommendations for its correction,” Proceedings of the 9-th Conference of heat plants of Yugoslavia,
Novi Sad, Yugoslavia (1995) pp.178–184. (In Serbian) 17. Lukic, N., Bojic, M., Modeling of steam-condensate system of heat-power plant by
method of linear programming, Proceedings of the 9-th Conference of Heat
Plants of Yugoslavia, Novi Sad, Yugoslavia (1995) pp. 185-196. (In Serbian) 18. Bojic, M., Papadakis, G., Kyritsis, S.,
"Air-to-Earth Heat Exchanger," Proceedings of International
Congress on Numerical Heat Transfer, Atlanta, USA, (1995). 19. M. Bojic, M. Tomic, N. Trifunovic, P. Durdevic,
“Energy Consumption of Industrial Pusher Furnaces: Use of a Mixture of High
Furnace Gas and Natural Gas as Fuel,” Proceedings of International Symposium
on Energetics and Power Supply Technologies, Novi Sad, Yugoslavia (1995)
p.33-41. 20. Bojic, M., Papadakis, G., Kyritsis, S.,
"Temperatures in Vicinity of Air-to-Earth Heat Exchanger, Proceedings
of International Symposium on
Energetics and Power Supply Technologies,
Novi Sad, Yugoslavia (1995) pp.160-168. 21. Bojic, M., Radivojevic, D., Voronjec, D.,
"Industrial Pusher Furnaces: Part 2 – Energy–Consumption Optimization of
the Heat–Recovery Coupling of two Pusher Furnaces," Proceedings of the
4th Greek National Congress on Mechanics, Xanti, Greece (1995) pp.975–981. 22. Bojic, M. Tomic, M., Lukic, N., Nikolic, D.,
"Industrial Pusher Furnaces: Part 1 – Influence of Slab Preheating to
Energy Consumption," Proceedings of the 4th Greek National Congress on
Mechanics, Xanti, Greece (1995)
pp.967–974. 23. M. Bojic, G. Savanovic, L., Radovic, N.,
Trifunovic, G. Ilic, M.Milovanovic, Energy Efficiency of the Application of
Peltier Cooling Devices in the Train Compartments using Coldness–Recovery
Devices, Proceedings of the 4th Greek National Congress on Mechanics, Xanti,
Greece (1995) pp.959-966. 24. M.Bojic, Computer application in rational use
of heat, Proceedings of Scientific-expert Meeting on Heat Management,
Kopaonik, Yugoslavia (1995) pp. 91-114. (In Serbian) 25. Bojic, M., Trifunovic, N., Stojanovic, B., Determination of energy loss by water flow
analysis in technological process, Proceedings of International Symposium on
Industrial waters, Pancevo, Yugoslavia (1995) pp.83-90. (In Serbian) 26. Bojic, M., Lukic, N., Use of intensive draft of
building in summer for energy saving necessary for its cooling, Proceedings
of 26. congress on air conditioning, heating and cooling, Ventilation and Air
Conditioning, Belgrade, Yugoslavia (1995) pp. 9-22. (In Serbian) 27. Bojic, M., Trifunovic, N., Lukic, N.,
Stojanovic, B., Decreased natural gas consumption in Pusher furnace Produces
Additional CO2 emission, Proceedings of International Conference on
Preventive Engineering and Living Environment, Nish, Yugoslavia (1995) pp.
F6-1- F6-4. 28. Bojic, M., Lukic, N., Babic, M., Milovanovic,
D., "Locally Ventilated Industrial Building with Heat Recovery:
Environmental Temperature Influence to Thermal Comfort and Energy
Consumption," Proceedings of the 5th International Conference Roomvent
96 on Air Distribution in Rooms, Vol.1 Yokohama, Japan (1996) pp. 149-154. 29. Milovanovic, D., Babic,M., Bojic,M.,
“Optimization of energy consumption in buildings through axial fan design”,
Proceedings of the 5th International Conference Roomvent96 on Air
Distribution in Rooms, Vol.1, Yokohama, Japan (1996) pp. 85-90. 30. Bojic, M., Babic, M., Milovanovic, D.,
Trifunovic, N., Stojanovic, B., "Heat gain Influence to Thermal Comfort
and Energy Consumption,” Proceedings of the 7th International Conference
Indoor Air `96 on Indoor Air Quality and Climate, Vol. 1, Nagoya, Japan (1996) pp. 227-232. 31. Babic, M., Milovanovic, D., Bojic, M.,
“Improvement of IAQ in Buildings through axial fan design” Proceedings of the
7th International Conference Indoor Air `96 on Indoor Air Quality and
Climate, Vol. 3, Nagoya, Japan (1996) pp. 1007-1012. 32. Bojic, M., Lukic, N., Stojanovic, B., Šaljic,
D., Papadakis, G., Kyritsis, S., "Energy Management by using
Air-to-Earth Heat Exchanger," Summaries 5 of CHISA96, 12th International
Congress of Chemical and Process Engineering, Praha, Czech Republic (1996)
p.45. 33. Bojic, M., Tomic, M., Jevtovic, D.,
"Influence of Oxygen Injection
and Refuse –Heat Use on Energy Consumption of Pusher Furnace,"
Proceedings of Balkan Conference on Metallurgy, Varna, Bulgaria (1996) pp.
88-93. 34. Bojic, M. Trifunovic, N. Jevtovic, D.
Dragicevic, S. "Effect of Refuse Fuel Use in Pusher Furnace to
Enlargement of Carbon Dioxide Emission," Proceedings of IV Yugoslav
Symposium on Metallurgy With
International Attendance, Vrnjacka banja, Yugoslavia (1996) pp.
541-544. 35. Bojic,M., Stojanovic.B., Jeftovic, D.,
Marjanovic, N., “Optimization of an energy system having a condensing turbine
with steam extraction”, Proceeding9s of International Symposium of Heat
Engineering, Heat Machines and Equipment and Road Vehicles, Timisoara,
Romania (1996) pp.40-50. 36. Raskovic, P., Bojic, M., Stoiljkovic, S.,
Optimization of energy system of industrial building with hot tools”,
Proceedings of 27 congress on heating, cooling and air conditioning,
Belgrade, Yugoslavia (1996) pp.94-104 (In Serbian). 37. Bojic, M., Dragicevic, S., Jevtovic, D.,
Optimization of the use of industrial water by using pinch methodology,
Proceedings of International symposium on hazardous waste and environment,
Vrnjacaka banja, Yugoslavia (1996) pp. 515-525. (In Serbian) 38. Bojic, M., Dragicevic, S., Optimization of
simultaneous use of thermal and electric energy in industry, Proceedings of
29. congress on air conditioning, heating and cooling, Ventilation and Air
Conditioning, Belgrade, Yugoslavia (1998), pp.109-118. (In Serbian) 39. Bojic, M., Heating and cooling of a building by
means of heat pump, heat recovery and air-to-earth heat exchanger:
installation efficiency optimization, Proceedings of 29. Congress on air
conditioning, heating and cooling, Ventilation and Air Conditioning, Belgrade,
Yugoslavia (1998), pp.139-146. (In Serbian) 40. Bojic, M., Petronijevic, K., The simulation of solar installation operation for heating sanitary hot water, Proceedings of 29. congress on air conditioning, heating and cooling, Ventilation and Air Conditioning, Belgrade, Yugoslavia (1998), pp. 161-167. (In Serbian) 41. Bojic, M. and Petronijevic, K. Simulation of an operation of a solar installation for domestic water heating. 1, 442-448. 1999. Athens, Greece. Energy and Agriculture towards the Third Millennium, Agricultural University of Athens, 2-5 June 1999. CIGR , EurAgEng, FAO, and UNESCO. 42. Bojic, M., Systems for district heating and
cooling: Japan experience, IX Savetovanje toplana Jugoslavije, Proceedings,TOPYU2000, 07-09. June 2000, 123-128.(in
Serbian). 43. M.Bojic, F. Yik, K.Wan, J.Burnett, Investigations of Cooling Loads in High-Rise Residential Buildings in Hong Kong, Proceedings of the ASME-ZSITS International Thermal Science Seminar, June 11-14, 2000, Bled, Slovenia, pp.505-510 44. M. Bojic, F. Yik, T.Y. Lo, M. Lee, Locating Air-conditioners and Furniture inside Residential Flats, In: Indoor Environment Technology Towards a Global Approach, CD of 7th Rehva World Congress: Clima 2000, Napoli 2001, Naples, Italy, 2001. 45. Yik, F., Bojic, M., Wan, K., The influence of envelope characteristics to the energy behavior of high-rise residential buildings, ABT 2002, Advances in Building Technology, Hong Kong, Referred article in press, 4-6 December 2002. 46. Bojic, M., Yik, F., Burnett, J., The airflow around and inside high-rise residential buildings in Hong Kong, ABT 2002, Advances in Building Technology, Hong Kong, Referred article in press, 4-6 December 2002. 1.
Zaric, Z., Bojic,
M., "Experimental Investigation of Heated Turbulent Jet in
Cross-Flow", Summaries of GAMM Congress 85, Dubrovnik, Croatia (1985)
p.3-46. 2.
Bojic, M.,
"Similarity Parameters of Non-buoyant Non-isothermal Mixing of Jet and
Cross-Stream ", Summaries of GAMM Congress 86, Dortmund, Germany (1986)
p. 101. 3.
Ilic, G., Bojic,
M., "An Analysis and Experiment on Heat Transfer for Fully Developed
Turbulent Flow in Concentric and Eccentric Annulus", Summaries of 9-th
International Congress of Chemical Engineering, Chemical Equipment Design and
Automation, Praha, Chzech Republic (1987) p. F5.57. 4.
Bojic, M.,
"Evaluation of Critical Steam-Traps Using a Binary Rating Method",
Summaries of CHISA '90, 10th International Congress of Chemical and Process
Engineering, Praha, Chzech Republic (1990). 5.
Bojic,M.
Mitrovic,S., "Software OKI 1.0 - Expert system for application of steam
traps in steam-condensate systems ", Summaries of workshop on
Applications of expert systems for control of energy consumption in industry
, Kragujevac, Yugoslavia (1992) p.1. (In Serbian) 6.
Bojic,M., Ilic,G., Randjic,D., Lukic,N., Study of the application of
expert system OKI 1.0 in industry, Summaries of workshop on Applications of
expert systems for control of energy consumption in industry, Kragujevac,
Yugoslavia (1992) p.2. (In Serbian) 7.
Bojic,M.,
"Multiple Influence Of Critical Operating Conditions To Steam Traps In
Steam And Condensate Systems", Summaries of CHISA'93, Praha, 11th
International Congress of Chemical and Process Engineering Czech Republic,
(1993) p. G8.92. 8.
Bojic,M.,
Lukic,N., "The influence of steam loss to use of refuse hot air for
building heating Summaries of the
Second First Workshop on Thermal Software in Industry, (1993), Kragujevac,
Yugoslavia, p.7. (In Serbian) 9.
Bojic,M.,
Lukic,N., "Analysis of steam-trap offer and heaters offer at our market
" Summaries of the Second Workshop on Thermal Software in Industry,
(1993), Kragujevac, Yugoslavia, p.8. (In Serbian). 10. Bojic,M., Lukic,N., "Evaluation of
investments and their effects to removal of incident situations because of
clear loss of steam" Summaries of
the Second Workshop on Thermal Software in Industry, (1993),
Kragujevac, Yugoslavia, p.9. (In Serbian) 11. Bojic,M., Lukic,N., "Evaluation of
investments and their effects to removal of non adequate use of steam "
Summaries of the Second Workshop on
Thermal Software in Industry, (1993), Kragujevac, Yugoslavia, p.10. (In Serbian) 12. Bojic,M., "Heuristic software for
visualization of steam flow rate through steam traps", Summaries of the First Workshop on Thermal Software in
Industry, (1993), Kragujevac, Yugoslavia, p.1. (In Serbian) 13. Bojic,M., Milovanovic,M., "Heuristic
software for selection of steam trap types Summaries of the First Workshop on Thermal Software in
Industry, (1993.), Kragujevac, Yugoslavia, p.2. (In Serbian) 14. Bojic,M., Lukic,N., Mitrovic, S.,
"Simulation software for visualization of energy loss due to
malfunctioning of steam-condensate installation ", Su9mmaries of the First Workshop on Thermal Software in
Industry, (1993.), Kragujevac, Yugoslavia, p.3. (In Serbian) 15. Bojic,M., Lukic,N., Mitrovic,S., "Software
for simulation of non proper use of steam with visualization of energy
loss", Summaries of the First
Workshop on Thermal Software in Industry, (1993.), Kragujevac, p.4. (In
Serbian) 16. Bojic,M., Lukic,N., "Simulation software
for calculation of efficiency of steam energy recuperation in industrial
buildings ", Summaries of the
First Workshop on Thermal Software in Industry, (1993), Kragujevac,
Yugoslavia, p.5. (In Serbian) 17. Bojic, M., "Software KD- Data base with
conduction coefficients for different materials", Summaries of the First Workshop on Thermal Software in
Industry, (1993.), Kragujevac, p.6. (In Serbian) 18. Bojic, M., "Software KR- Calculation of
coefficients of heat transmission for walls of building envelope",
Summaries of the First Workshop on
Thermal Software in Industry, (1993.), Kragujevac, Yugoslavia, p.7. (In Serbian) 19. Bojic, M., Milovanovic, M., "Software GRE
Calculation of building heat loss and selection of radiators of fan-coil
type", Summaries of the First
Workshop on Thermal Software in Industry, (1993.), Kragujevac,
Yugoslavia, p.8. (In Serbian) 20. Bojic, M., Knezevic,V., "Software RR -
Selection of radiators of Jugoterm type Summaries of the First Workshop on Thermal Software in
Industry, (1993), Kragujevac, Yugoslavia, p.9. (In Serbian) 21. Bojic, M., Knezevic, V., Malesevic, J.,
"Software for selection of the valve position of branches, verticals,
and radiators to balance flow in building heating loops", Summaries
of the First Workshop on Thermal
Software in Industry, (1993), Kragujevac, Yugoslavia, p.10. (In Serbian) 22. Bojic, M., Milovanovic, M., "Software ZGRA
- Simulation of temperature variation in building due to variation of outside
temperature ", Summaries of the
First Workshop on Thermal Software in Industry, (1993), Kragujevac,
Yugoslavia, p.11. (In Serbian) 23. Bojic, M., Lukic, N., "Software GUPDI for
steam loss because of old installations", Summaries of the Second First Workshop on Thermal
Software in Industry, (1993), Kragujevac, Yugoslavia, p.1(In Serbian) 24. Bojic, M., Lukic, N., "Software LINEAR for
optimal use of steam refuse heat in industrial buildings", Summaries
of the Second First Workshop on
Thermal Software in Industry, (1993), Kragujevac, Yugoslavia, p. 2. (In
Serbian) 25. Bojic, M., Lukic, N., "Software BOK - data
base of steam traps available at market", Summaries of the Second First Workshop on Thermal
Software in Industry, (1993), Kragujevac, Yugoslavia, p. 3. (In Serbian) 26. Bojic, M., Lukic, N., Knezevic, V.,
"Software BOGT - data base of heaters available at market ",
Summaries of the Second First
Workshop on Thermal Software in Industry, (1993), Kragujevac, Yugoslavia, p.
4. (In Serbian) 27. Bojic, M., Lukic, N., "Software ISOP-
effects of investment to avoid steam loss ", Summaries of the Second First Workshop on Thermal
Software in Industry, (1993), Kragujevac, Yugoslavia, p.5. (In Serbian) 28. Bojic, M., Lukic, N., "Software INUP-
effects of investment to avoid non-adequate use of steam ", Summaries
of the Second First Workshop on
Thermal Software in Industry, (1993), Kragujevac, Yugoslavia, p.6. (In
Serbian) 29. Radivojevic,P., Bojic,M., "Experiments
with thermal siphon ", Extended summaries of IX Symposium of Yugoslav
society of heat engineers JUTERM'93, Belgrade, Yugoslavia (1993) pp. 37-38.
(In Serbian) 30. Bojic,M., Ilic,G., "Some possibilities for
a coarse control of a steam-condensate system," Extended summaries of IX
Symposium of Yugoslav society of heat engineers JUTERM'93, Belgrade,
Yugoslavia (1993) pp. 209-210. (In Serbian) 31. Lukic,N., Bojic,M., "Optimization of
energy systems of industrial buildings ", Extended summaries of IX
Symposium of Yugoslav society of heat engineers JUTERM'93, Belgrade,
Yugoslavia (1993) pp. 193-194. (In Serbian) 32. Milovanovic, M., Bojic, M., "Research in
thermal behavior of buildings with slanted roof ", Extended summaries of
IX Symposium of Yugoslav society of heat engineers JUTERM'93, Belgrade,
Yugoslavia (1993) pp. 191-192. (In Serbian) 33. Raskovic,P., Bojic, M., "Influence of the
distribution of masonry and isolation in slab to thermal behavior of
buildings ", Extended summaries of IX Symposium of Yugoslav society of
heat engineers JUTERM'93, Belgrade, Yugoslavia (1993) pp.195-196. (In
Serbian) 34. Tomic, M., Bojic, M., Jankes, G., Gosic, D.,
"Some results of measurement of energy consumption at pusher furnace
under application of different fuels ", Extended summaries of IX
Symposium of Yugoslav society of heat engineers JUTERM'93, Belgrade,
Yugoslavia (1993) pp. 211-212. (In Serbian) 35. Mitrovic,S., Bojic, M., "Expert system
OKI1.0 to avoid incident situations in manipulation with steam traps in steam
and condensate systems ", Extended summaries of IX Symposium of Yugoslav
society of heat engineers JUTERM'93, Belgrade, Yugoslavia (1993) pp.113-114.
(In Serbian) 36. Malesevic,J., Knezevic,V., Bojic,M.,
"Software for balancing of pipe loops of central heating systems",
Extended summaries of IX Symposium of Yugoslav society of heat engineers
JUTERM'93, Belgrade, Yugoslavia (1993) pp.117-118. 37. Knezevic,V., Bojic,M., "Software for
selection of plate radiators,” Extended summaries of IX Symposium of Yugoslav
society of heat engineers JUTERM'93, Belgrade, Yugoslavia (1993) pp.119-120.
(In Serbian) 38. M.Bojic, V.Knezevic, N.Lukic,
J.Malesevic," Influence of outside temperature to use of refuse heat
under local ventilation," Proceedings of Papers and Summaries of
Scientific-expert Meeting on Industrial Energetics '94, Belgrade, Yugoslavia
(1994) p. 496. (In Serbian) 39. G.Ilic, M., Bojic, V., Stefanovic, M.,
Marinkovic, "Influence of the geometric parameters of the flue gas
channels on thermal power and efficiency of solid-fuel burning kitchen
stoves", Summaries on Energy Forum 1995, Varna, Bulgaria, (1995), pp.18–19. 40. V.Stefanovic, D.Stefanovic, G., Ilic, M.,
Bojic, An Universal Computer Model of a Building Basis and Concept of a
Program System P.C.G. in Designing
CHR Installations, Summaries on Energy Forum 1995, Varna, Bulgaria
(1995) pp.38–39. 1.
Bojic, M.,
"Computer Package for Calculation of Energy Savings in Non-Residential
Buildings", Lecture at Institute of Heat Engineering, Department of
Energy Engineering, Technical University of Slaska, Gliwice, Poland, (1988).
(19 pages) 2.
Bojic,M.,
"Energy systems in industry: Industrial Buildings and Steam-trap
Types", Lecture at Fourth Summer School on Thermodynamics: Theory of
Energy Management in Industrial Plants, Ustron, Poland (1989). (11 pages) 3.
Bojic, M.,
"Possibilities of use of different steam traps in industrial energy
systems", Lecture at Mechanical Engineering Faculty, Sarajevo, Bosnia
and Hercegovina (1989). (14 pages). (In Serbian) 4.
Bojic,M.,
"New Software "AZMA" For Obtaining Efficiency Of Heat Recovery
From Local Ventilation", Lecture at Chech High Technical University in
Praha, Faculty of Mechanical Engineering, Praha, Czech Republic, (1991). (14
pages) 5.
Bojic,M.,
"The influence of Slab Non-homogeneity to Heat Transfer with Example of
the Building", Lecture at Mechanical Engineering Faculty of Technical
University at Temisoara, Romania, (1993). (9 pages). 6.
Bojic,M., Lukic,
N., "Software package TOPHIS" Lecture at Mechanical Engineering
Faculty at Timisoara, Romania (1993)
pp.1-3. 7.
Bojic, M.,
"Optimization of the Heat-Recovery Coupling of two Pusher Furnaces
running with the Air of different Oxygen Percentage", Lecture at
Institute of Thermal Technology, Department of Environmental Engineering and
Energy, Technical University of Silesia, Gliwice, Poland, (1994). (5 pages). 8.
Tomic, M., Bojic,
M., "Influence of Oxygen-Injection Position to Energy Consumption of
Pusher Furnace", Lecture at Institute of Thermal Technology, Department
of Environmental Engineering and Energy, Technical University of Silesia,
Gliwice, Poland (1994). (5 pages) 9.
Bojic, M.,
“Softwares POTIS for the simulation of Energy Consumption of Pusher Furnaces
and POREK for the simulation of Energy Consumption of Heat Recovery coupled
Pusher Furnaces", Lecture at Institute of Thermal Technology, Department
of Environmental Engineering and Energy, Technical University of Silesia,
Gliwice, Poland, (1994). (2 pages). 10. Bojic, M., “Energy Research at the Energy
Management Center of Kragujevac University, Yugoslavia,” Lecture at
Department of Architecture, Nagoya University, Nagoya, Japan (1997). (58
pages). 11. Bojic, M., “Modeling and Optimal Design/Control
of Energy Systems in Urban Scale-Review of my Previous and Current Research
Activities,” Lecture at Center for Integrated Research in Science and
Engineering, Nagoya University, Nagoya, Japan (1997). (76 pages) 12. Bojic, M., “Facts on 3E: Energy, Ecology, and Economy in Yugoslavia (Europe),” Lecture at Department of Architecture, Nagoya University, Nagoya, Japan, (1997). (38 pages) 13. Bojic, Heat rejection into recessed spaces outside high-rise residential buildings (research at Hong Kong Polytechnic University), Invited lecture, Hong Kong University, Department of Mechanical Engineering, 7 June 2002. 1.
Bojic, M.,
"Influence of thermal pollution of Sava river at Obrenovac to oxygen
absorption and life in river”, Topical report of Mechanical engineering
faculty at Kragujevac, Kragujevac Yugoslavia, (1975). (In Serbian) 2.
Bojic, M., Babic,
M., Arsic, Z., "Experimental anemometer investigation of
temperature-velocity field of three dimensional flow", Report on XIII
seminar on heating, cooling and air-conditioning, Belgrade, Yugoslavia,
(1982). (In Serbian) 3.
Bojic, M.,
Cogeneration of electrical energy and heat by using endoreversible
Rankine cycle, XXVII Kraftwerkstechnische Kolloquium, Dresden,
Germany (1995) p.SP10. 4.
Bojic, M., Tomic,
M., Some possibilities of heat
generation recovery via its recovery in pusher furnace, XXVII Kraftwerkstechnische Kolloquium, Dresden,
Germany (1995) p.BP15. 5.
Bojic, M.,
Papadakis, G., Kyritsis, S., "Some Possibilities of Heat Production by
using Earth to Air Heat Exchanger," XXVII Kraftwerkstechnische Kolloquium, Dresden, Germany (1995) p.RP9. 6.
Bojic, M.,
Software to Calculate Thermal Behaviour of Heat Storage in Soil, Topical
report, Center for Energy Management, Kragujevac, Yugoslavia, Center for
Integrated Research in Science and Engineering, Nagoya, Japan, 1998. g. Selected software realized under supervision of Prof. M. Bojic (Programming languages: prolog, basic, Fortran, C, C++) 1.
Expert systems
for control of energy consumption in steam and condensate systems. 2.
Software for
simulation of use of earth-air heat exchanger for heating or cooling of
industrial buildings (passive use of solar energy). 3.
Software for
simulation of energy consumption in industrial furnaces using refuse heat and
different fuels. 4.
Software for
simulation of heat recovery in a space heating and ventilation system. 5.
Software for
linear programming optimization of energy savings in an industrial building
with several available hot refuse flows. 6.
Software for
dynamic simulation of thermal behavior of the buildings. 7.
Software for
linear programming optimization of boiler-recovery-heat exchangers. 8.
Software for
simulation of thermoelectric cooling of a train carriage by using a
coldness-recovery device. 9.
Software for
mixed integer linear programming optimization of heat distribution within a
local heating system. 10. Software for mixed integer linear programming
optimization of energy systems having a boiler, turbine, and heat pump. 11. Software for dynamic-programming optimization of
heating and cooling of a building by means of heat pump, heat recovery and
air-to-earth heat exchanger. 12. Software for a simulation of solar-installation
operation for heating domestic hot water. 13.Software to calculate thermal behavior of heat
storage in soil. j. Served as referee in following
journals 1. Heat in Industry, Yugoslav Journal 2. Heat Engineering, Yugoslav Journal 3. Facta Universitatis, Series: Mechanical Engineering, Yugoslav
International Journal (1996-) 4. Energy-The International Journal, Pergamon Press (1997-) 5. Proceedings of the Institution of Mechanical Engineers Part A, England (1998-) 7.
Proceedings of the Institution of Mechanical
Engineers Part E, England (1998-) 8.
International
Journal of Numerical Methods for Heat & Fluid Flow (1999-) 9.
ASHRAE
Transactions (2001-)
|